title: 'BREEAM In-Use: what the operational assessment asks for, and the data that backs it'
description:
    'BREEAM In-Use International Commercial V6: Part 1 Asset and Part 2 Management, ratings bands, and the metered
    evidence that backs operational credits.'
image: /images/articles/breeam-in-use.webp
image_alt:
    'The Vertex Green Hub building with metal mesh screens and lush plants by a canal, a green-certified commercial
    facade'
published_date: '2026-10-26 12:00'
---

_Photo: The Vertex Green Hub building. Photo by
[Nadia Assabella](https://unsplash.com/@nadiaasss_29?utm_source=frostlogic-mission-control&utm_medium=referral) on
[Unsplash](https://unsplash.com/?utm_source=frostlogic-mission-control&utm_medium=referral)._

**BREEAM In-Use** is the performance scheme for buildings that already operate. It does not score a design drawing. It
scores how the asset is built and how it is run, with evidence that can survive an assessor's review. Operators who
treat it as a once-a-year PDF rebuild discover the same failure mode every cycle: the credits describe continuous
operation, and the evidence was assembled in a hurry from estimates.

This Field Note covers what the current international commercial scheme asks for, which categories lean on metered and
sensor data, and how continuous monitoring shortens the evidence conversation. It is not a substitute for the BRE
technical manuals or a licensed assessor. FrostLogic Explore does not assess BREEAM, issue certificates, or guarantee a
rating. It keeps operational evidence measurable between assessments.

## What BREEAM In-Use is

BREEAM (Building Research Establishment Environmental Assessment Method) is BRE's family of sustainability assessment
schemes. **BREEAM In-Use** targets existing commercial assets. It is distinct from BREEAM New Construction, which
assesses design and construction of new buildings, and from major-refurbishment schemes aimed at deep retrofit.

The framing that matters for operators is performance-based: ratings come from scored answers about the building as an
asset and about how it is managed day to day. A shiny lobby does not substitute for missing energy sub-meters. A policy
document does not substitute for consumption records that do not exist.

If you need the product view of continuous BREEAM evidence collection, start at
[BREEAM compliance, monitored continuously](/compliance/breeam/). This article stays on the informational side: what the
operational assessment is asking for, and what data actually backs it.

## BREEAM In-Use International Commercial Version 6

The scheme most Nordic and international portfolios meet today is **BREEAM In-Use International Commercial Version 6**
(BIU International Commercial Technical Manual V6). Parts are independently scored:

| Part                                | Focus                              | What it mainly tests                                                          |
| ----------------------------------- | ---------------------------------- | ----------------------------------------------------------------------------- |
| **Part 1 — Asset Performance**      | Physical building and base systems | Fabric, installed systems, inherent efficiency of the asset                   |
| **Part 2 — Management Performance** | How the asset is operated          | Policies, monitoring, maintenance, reported consumption and indoor conditions |

Either part can be certified alone. Many owners pursue both; the scheme does not force a single combined score.

Older materials still mention **Part 3 Occupier Management**. Treat that as prior/legacy framing. Current V6 commercial
materials, and how SGBC presents the scheme in Sweden, use the two-part Asset / Management split.

BRE has signalled that a Version 7 update for In-Use is expected later in 2026. Until that manual is live for
International In-Use, operate against V6 and re-read the assessor's brief when V7 lands.

## Nine category families

V6 organises credits across nine category families:

1. **Energy**
2. **Health & Wellbeing**
3. **Transport**
4. **Resilience**
5. **Resources**
6. **Water**
7. **Land Use & Ecology**
8. **Management**
9. **Pollution**

Not every category is a sensor problem. Fabric questions, ecology surveys, transport plans and installed-kit inventories
need drawings, site surveys and procurement records. Operational data mostly backs **management and performance
evidence**: energy monitoring and reporting, indoor air quality and thermal bands, water use and leak detection, and the
routines that prove those streams are watched.

That split is why a quarterly spreadsheet rebuild fails. Asset facts change slowly. Management evidence decays every
week the meters are not read, the thresholds are not checked, and the exception queue is empty.

## Ratings bands

SGBC and BRE summarise the percentage bands as follows (score against the applicable part):

| Rating       | Score |
| ------------ | ----- |
| Outstanding  | ≥ 85% |
| Excellent    | ≥ 70% |
| Very Good    | ≥ 55% |
| Good         | ≥ 40% |
| Pass         | ≥ 25% |
| Acceptable   | ≥ 10% |
| Unclassified | < 10% |

The band is the outcome of the assessor's scored evidence pack, not a marketing label you pin on a brochure after a
single winter of mild bills.

## Process reality: assessor, platform, Green Book Live

A licensed **BREEAM In-Use Assessor** runs the assessment. Evidence sits on the BRE platform. Certified assets and
assessors are listed via Green Book Live. Your facilities team can collect meters, policies and logs; the assessor still
owns the formal scoring path.

Explore does not replace that assessor. Continuous monitoring can cut the weeks spent reconstructing evidence, and it
can keep thresholds visible between certifications. It does not issue the certificate.

## Sweden: international manual, not a Swedish In-Use adaptation

There is **no Swedish-adapted BREEAM In-Use**. Sweden uses the **international** manual for In-Use assessments. SGBC
explains the scheme on its certification pages; the operational rules still come from BRE's international commercial
manual, not a local credit rewrite.

**BREEAM-SE** (SGBC) covers New Construction and, under the renewed BRE partnership, Refurbishment. That is the right
tool for new-build and major retrofit in Sweden. It is not a substitute for In-Use on existing stock that needs an
operational rating. Do not invent Swedish In-Use credit codes; use the international category language and your
assessor's V6 issue list.

## Data that backs an operational assessment

Assessor-ready operational evidence usually includes some mix of:

- **Continuous sub-metered energy** by meaningful end-use or zone, not a single annual total reconstructed from invoices
- **CO₂ / IAQ** traces in occupied zones, with thresholds the team actually watches
- **Thermal bands** (operative or space temperature against the agreed comfort range)
- **Water** consumption plus **leak detection** on major flows
- **Maintenance and policy evidence**: how monitoring is governed, how exceptions are closed, how consumption is
  reported

Estimates lose arguments. Metered time series win them because the assessor can see continuity, gaps and breaches
instead of a single polished annual figure. That is also why [IPMVP](/articles/ipmvp/) and certification are adjacent
but not the same job: proving a discrete saving is not the same as scoring an operational scheme, and neither accepts a
slide-deck percentage as evidence.

Portfolio carbon and pathway work has the same meter dependency. A [CRREM pathway](/articles/crrem-pathway/)
Misalignment Year that rests on certificate estimates moves the year without moving the building; BREEAM In-Use
Management evidence that rests on the same estimates fails for the same reason.

Quarterly rebuilds fail for boring reasons. Someone left, the sub-meter map was never finished, the BMS trend logs
rolled off, and the comfort complaints never became a dataset. Continuous collection does not invent credits. It stops
the evidence from disappearing between assessments.

## How Explore keeps continuous compliance honest

FrostLogic Explore is Sensor Intelligence for commercial and industrial estates. For BREEAM-shaped work it watches the
sensor thresholds you care about, ranks breaches in a queue, and exports audit-ready packs toward assessor workflows.
The product page is [continuous BREEAM compliance](/compliance/breeam/).

Explore is not a licensed BREEAM In-Use Assessor. It does not issue BRE certificates and it does not guarantee
Outstanding, Excellent, or any other band. Writes start off; you grant scopes when you want write-back. Prefer read
evidence first: meters, IAQ, thermal and water streams you already run.

The honest product bridge is short. Keep the time series. Keep the breach history. Hand the assessor continuity instead
of a rebuilt spreadsheet. For the compliance hub that sits next to BREEAM, LEED and Nordic Swan, see
[compliance](/compliance/).

## FAQ

**What is BREEAM In-Use?** BREEAM In-Use is BRE's performance assessment scheme for existing buildings. It scores asset
and management performance with evidence of how the building is built and how it is operated, unlike New Construction
schemes that focus on design and build.

**What is BREEAM In-Use International Commercial Version 6?** It is the current international commercial technical
manual (V6) most portfolios meet outside specialised national adaptations. It scores Part 1 Asset Performance and Part 2
Management Performance independently.

**What is Part 1 Asset Performance?** Part 1 scores the physical building and base systems: fabric, installed plant and
the inherent efficiency of the asset. It can be certified without Part 2.

**What is Part 2 Management Performance?** Part 2 scores operational policies, monitoring, maintenance and reported
consumption and conditions. It is where continuous metering and indoor-environment evidence usually matter most. It can
be certified without Part 1.

**Is there a Swedish BREEAM In-Use adaptation?** No. Sweden uses the international In-Use manual. BREEAM-SE covers New
Construction and Refurbishment via SGBC; it complements In-Use for new-build and major retrofit, and does not replace
In-Use on existing operational stock.

**What operational data backs BREEAM In-Use credits?** Mostly management and performance evidence: sub-metered energy,
IAQ and thermal bands, water and leak detection, plus the monitoring and reporting routines around those streams.
Fabric, ecology and transport questions still need drawings, surveys and policy documents.

**Does FrostLogic Explore certify BREEAM In-Use or replace the assessor?** No. Explore is not a licensed BREEAM assessor
and does not issue certificates or guarantee a rating. It provides continuous sensor evidence and audit-ready export
toward assessor workflows on the [BREEAM compliance](/compliance/breeam/) product path.

**Why do quarterly spreadsheet rebuilds fail certification prep?** Because management evidence is continuous. Gaps,
breaches and missing sub-meters show up when the assessor asks for the period, not when the spreadsheet was last tidied.
Metered time series beat annual estimates for the same reason audits reject unverifiable savings claims.

## What's your building not telling you?

If BREEAM In-Use evidence still lives in a pre-submission scramble, bring the meters and sensors you already have. We
listen first, then say straight whether continuous compliance monitoring helps on your estate. 30 or 60 minutes, your
pick. No commitment either way. [Talk it through](/contact-us/).

Not ready for a call? Get your [Building Intelligence Score](/building-intelligence-score/). Twelve questions, a free
score, and a clear view of where the building is leaking value.