Explore capability

Automation for AI building control.

The ranked queue proposes the change. You grant write access one scope at a time, and choose whether each change waits for a person or runs on its own.

Book a time directly
  • Writes only where you allow
  • Shows its work before anything moves
  • Included in Professional
Proposal · AHU-04 · Floor 4Illustrative

Lower supply-air setpoint on unoccupied weekends

20.5 °C19.5 °CSat–Sun, 00:00–24:00

Evidence
Return air 2.1 °C above target for 3 consecutive weekends. Occupancy sensors: 0.
Reasoning
VAV boxes fully closed, so the AHU is heating air nobody uses. The physics model confirms no comfort penalty.
Expected effect
-4.2 % heating kWh on this AHU, about 3 400 kr per month. Reversible.
Scope
Floor 4 HVAC setpoints · granted · human review
Write via Edge Agent · BACnet · reversible

From finding to write-back

Detection ranks the problem. Automation is where you let Explore act.

Automation is Explore's permissioned BMS write-back for AI building control. The BMS analytics layer detects, forecasts and ranks. Automation is the action layer on top: it proposes a change, shows the reasoning and the expected effect, then writes only inside a scope you granted, through the FrostLogic Edge Agent.

Detect

BMS analytics

Reads your BMS, meters and sensors. Finds drift, waste and faults. Ranks them by the cost of waiting.

Reads only

Propose

Automation

Turns a ranked finding into a concrete change: a setpoint, a schedule or a control tweak, with evidence and expected effect.

You decide: review or automatic

Write

Edge Agent

Installed on the BMS machine. Writes only to points inside a granted scope. Everything else stays untouched.

Stays off until you grant a scope

Writes start offNew installs ship with no write scopes granted.
Reasoning on every changeNothing invented at inference, nothing invented at action.
Not a BAS, not a CMMSYour BMS stays the control layer. Work orders stay in your CMMS.
Included in ProfessionalNot an add-on, not a higher tier. See pricing.

Scoped write access

You set the leash, one scope at a time.

A scope is a set of BMS points you choose to open. Inside each scope you pick the mode. Outside it, Explore can read but never write.

ScopeBMS pointsWrite mode
Floor 4 HVAC setpoints12 points · AHU-04, VAV 4.01–4.11
Automatic
Chiller plant schedule6 points · CH-01, CH-02, primary pumps
Human review
Lighting schedules40 points · all floors
Reads only
Fire and life safetyNot exposed to Explore
No scope
IllustrativeExplore writes automaticallyExplore proposes, a person approvesExplore reads onlyNever written

That is supervisory control with a leash: Explore proposes, and you set how much runs unattended. New installs ship with no scopes granted, so nothing is written until you turn a scope on.

What Automation does

Propose, schedule, grant, write

Proposals with reasoning

Every proposed change lands with the evidence trail, the physics reasoning, and the expected effect. Nothing invented at inference, and nothing invented at action either.

Time and event triggers

Schedules can fire on a clock or on an event from the ranked queue. Useful for HVAC optimization where a setpoint or schedule only makes sense under a stated condition.

Human review or automatic

Inside a granted scope you choose the leash: wait for a person, or let the change run on its own. Points outside that scope stay untouched.

Scoped write via Edge Agent

The FrostLogic Edge Agent installs on the BMS machine and reads and writes points. Write access starts off. You turn it on one scope at a time.

How it works

Propose, decide, write

Propose

Change with reasoning

Explore proposes a setpoint, schedule or control tweak with the evidence, the reasoning and the expected effect.

Decide

Review or auto

Inside each granted scope you choose: wait for a person, or let matching proposals run automatically.

Write

Scoped Edge Agent write

The FrostLogic Edge Agent writes only to the points inside that scope. Everything else stays untouched.

How the three approaches compare

Static schedules, black-box autonomy, or permissioned write-back

Automation: raw BMS schedules, fully autonomous write-back, and Explore compared
Raw BMS schedulesFully autonomous write-backExplore Automation
Starting stateHardcoded timers and setpointsWrites continuously once connectedRead-only until you grant a scope
What you seeSchedule table, little contextOpaque control loopProposal with reasoning and expected effect
Who decidesWhoever edited the schedule lastThe vendor modelYou set human review or auto per scope
Scope of writeWhatever the schedule touchesBroad HVAC write-back by defaultOnly points inside a granted scope
TriggerClock onlyContinuous closed loopTime or event from the ranked queue
Honesty postureTransparent but dumbFast, hard to auditShows its work; you set the leash

At a glance

The mechanics

Automation sits on top of the same sensor-intelligence layer as detection and forecasting. It does not replace the BMS, the integrator's logic, or a CMMS work order.

OffDefault

Explore reads. Nothing is written.

Human reviewThe proposal waits

A person approves the change before it is written.

AutomaticRuns on its own

Only inside the granted scope.

Questions

Automation, answered

Yes, once you turn it on. Write access starts off. You grant it one scope at a time, and Explore proposes the change with its reasoning and the expected effect before anything moves. You choose whether that proposal waits for someone to approve it, or runs automatically inside the scope you set. Points outside that scope stay untouched.

Explore starts read-only. No write scopes are granted out of the box, so the Edge Agent does not write anything until you turn a scope on. Read-only until you grant a scope.

No. Explore is Sensor Intelligence. It reads your existing BMS and can write back inside scopes you grant. It does not replace the control system, the integrator logic, or a BAS. Building automation systems remain the control layer; Automation is the permissioned action layer on top.

No. Explore can propose a change or surface a finding for a technician, but work-order scheduling, spare parts and crew dispatch stay in your CMMS. Automation writes to BMS points you grant; it does not become your maintenance management system.

Automation is included in the Professional package. It is not sold as an add-on and it is not locked behind a higher tier.

Some products push continuous closed-loop HVAC changes with little operator visibility. Explore shows its work: every proposal carries reasoning and expected effect, and you set how much runs unattended inside each granted scope. We do not match blanket autonomy. You keep the leash.

See Automation against your own BMS

Connect one building, keep writes off until you are ready, and walk through a proposed change with its reasoning before anything moves.